1.
J Radiol Prot ; 44(2)2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38537259

RESUMEN

Diagnostic reference levels (DRLs) and achievable doses (ADs) provide guidance to optimise radiation doses for patients undergoing medical imaging procedures. This multi-centre study aimed to compare institutional DRLs (IDRLs) across hospitals, propose ADs and multi-centric DRLs (MCDRLs) for four common x-ray examinations in Sri Lanka, and assess the potential for dose reduction. A prospective cross-sectional study of 894 adult patients referred for abdomen anteroposterior (AP), kidney-ureter-bladder (KUB) AP, lumbar spine AP, and lumbar spine lateral (LAT) x-ray examinations was conducted. Patient demographic information (age, sex, weight, BMI) and exposure parameters (tube voltage, tube current-exposure time product) were collected. Patient dose indicators were measured in terms of kerma-area product (PKA) using a PKAmeter. IDRLs, ADs, and MCDRLs were calculated following the International Commission on Radiological Protection guidelines, with ADs and MCDRLs defined as the 50th and 75th percentiles of the median PKAdistributions, respectively. IDRL ranges varied considerably across hospitals: 1.42-2.42 Gy cm2for abdomen AP, 1.51-2.86 Gy cm2for KUB AP, 0.83-1.65 Gy cm2for lumbar spine AP, and 1.76-4.10 Gy cm2for lumbar spine LAT. The proposed ADs were 1.82 Gy cm2(abdomen AP), 2.03 Gy cm2(KUB AP), 1.27 Gy cm2(lumbar spine AP), and 2.21 Gy cm2(lumbar spine LAT). MCDRLs were 2.24 Gy cm2(abdomen AP), 2.40 Gy cm2(KUB AP), 1.43 Gy cm2(lumbar spine AP), and 2.38 Gy cm2(lumbar spine LAT). Substantial intra- and inter-hospital variations in PKAwere observed for all four examinations. Although ADs and MCDRLs in Sri Lanka were comparable to those in the existing literature, the identified intra- and inter-hospital variations underscore the need for dose reduction without compromising diagnostic information. Hospitals with high IDRLs are recommended to review and optimise their practices. These MCDRLs serve as preliminary national DRLs, guiding dose optimisation efforts by medical professionals and policymakers.


Asunto(s)
Niveles de Referencia para Diagnóstico , Uréter , Adulto , Humanos , Rayos X , Dosis de Radiación , Vejiga Urinaria , Sri Lanka , Estudios Transversales , Estudios Prospectivos , Abdomen , Valores de Referencia , Riñón
2.
J Radiol Prot ; 43(4)2023 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-37738966

RESUMEN

The establishment of diagnostic reference levels (DRLs) is an effective tool for optimising radiation doses delivered to patients during medical imaging procedures. This study aimed to compare the institutional DRLs (IDRLs) and propose a multi-centric diagnostic reference level (MCDRL) for chest x-ray examinations in adult patients in Sri Lanka. A prospective cross-sectional study was conducted with 1091 adult patients across six major tertiary care hospitals. Data on patient characteristics, such as age, sex, weight, and body mass index, and exposure parameters, such as tube voltage (kVp) and the product of tube current and exposure time (mAs), were collected. Patient doses were measured in terms of kerma-area product (PKA) using a PKAmeter mounted on the collimator of the x-ray tube. IDRLs were computed for each hospital according to the International Commission on Radiological Protection guidelines, and the 75th percentile PKAwas used to propose the MCDRL. The relationship between patient weight and exposure parameters was examined using Spearman's rank correlation to investigate the radiographic practice among hospitals. Results showed that IDRLs varied from 0.10 to 0.26 Gy cm2. The proposed MCDRL was 0.23 Gy cm2, substantially higher than the recently published DRLs from other countries. The median kVp ranged from 95 to 104, while mAs ranged from 2.5 to 5.6. Large variations in the PKAand exposure parameters were observed within and among hospitals. The elevated PKAvalues observed in this study were mostly due to the use of high mAs in clinical practice. The weak correlation observed between patient weight and exposure parameters suggests the need to standardise examination protocols concerning patient size. The observed dose variations demonstrate the need for the establishment of national DRLs. Until then, the proposed MCDRL can be considered as the benchmark dose level for chest x-ray examinations in Sri Lanka.

3.
J Appl Clin Med Phys ; 23(12): e13852, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36448529

RESUMEN

The present study was conducted as part of a comprehensive work to establish National Diagnostic Reference Levels (NDRLs) in Sri Lanka for the first time. DRLs can be used as an effective optimization tool for identifying unusually high or low patient doses during X-ray examinations. This study aims to propose institutional DRLs (IDRLs) by measuring the kerma-area product (KAP) of adult patients undergoing routine projection X-ray examinations. The median and the 75th percentile KAP values obtained were compared with that of the single institution KAP values reported from India and Greece. This descriptive cross-sectional study was conducted in a public hospital in Uva province, Sri Lanka, with 400 adult patients aged 18-87 years and weighing 58 ± 20 kg. The patient-specific information (age, sex, weight, and height) and corresponding exposure parameters (tube voltage and current-exposure time product) were obtained. The KAP values were measured, and descriptive statistics were utilized for data analysis. The median KAP values obtained were proposed as IDRLs. The IDRLs in Gy.cm2 were 0.23 for cervical spine anterior-posterior (AP), 0.19 for cervical spine lateral (LAT), 0.10 for chest posterior-anterior (PA), 0.06 for knee joint AP, 0.05 for knee joint LAT, 1.47 for KUB AP, 0.85 for lumbar spine AP, 1.97 for lumbar spine LAT, 0.29 for shoulder joint AP, 0.61 for skull PA, and 0.60 for skull LAT examinations. The maximum to minimum ratio of KAP values ranged from 2.4 for KUB AP to 6.3 for the cervical spine AP examinations. The median and the 75th percentile of most of the examinations were comparable to corresponding KAP values reported by the countries mentioned above, except for the skull PA and LAT examinations. Accordingly, interquartile ranges of exposure parameters are recommended for skull examinations to improve the optimization of patient doses.


Asunto(s)
Protección Radiológica , Intensificación de Imagen Radiográfica , Adulto , Humanos , Dosis de Radiación , Niveles de Referencia para Diagnóstico , Sri Lanka , Estudios Transversales , Valores de Referencia